Click here to download the Mini Autoclave Brochure


page38_1wtmk

The Mini Autoclave Sprayer System consists of a 1/3HP (0.5kW) x 250 PSI (17BAR) pump unit enclosed in a vandal resistant 304L 20 Gauge stainless steel chassis and cabinet to lock up a 5 gallon (20 Liter) pail of odor neutralizer, a 25’ (7.5M) section of UV resistant manifold hose and a treaded 0.03GPM (110 cc per min) x 50 micron stainless steel misting nozzle.

The pump unit is secured to a wall close by the autoclave unit area and the threaded nozzle is screwed through any available port on the pressure vessel  to spray 50 micron sized odor neutralizer droplets directly inside the chamber and at the odor source. Signal inputs to each of the timers on the Mini Autoclave System are connected to the Autoclave control panel

Easy-to-use controls are located in a NEMA 4X enclosure behind a Lexan cover that can be locked if required. The operation of the unit is controlled using two simple timers, the first timer controls how often and how long the unit sprays during the autoclaving process, the second timer controls how long the unit sprays during the door opening process. Indicator lights show when the unit has power, another light shows when the unit is in operation and a buzzer and separate light alerts the user if the unit has run empty of odor neutralizer. Controls are manufactured and assembled to meet NEC and IEC Standards. Standard power supply is 115 vAC / 60Hz, 230 vAC / 50Hz is available.